- FLUKE Infrared ThermometerDeskripsi:- No contact type. Compact, low price and easy to operate.- Emissivity setting can be changed to match the material of the object.atribut:
- Minimum Temperature Display (°C): 0.1
- FLUKE Multimeter Digital (Multitester)Deskripsi:Designed for basic electrical testing and provides reliable measurements to residential, commercial and heating and air conditioning technicians. This lightweight multimeter is small enough to fit in one hand, yet rugged enough to withstand daily use in the coming years. If you want a professional and affordable multimeter, this Digital Multimeter is the best choice.atribut:
- DC Voltage Range (V): 6/60/600 (DC)
- Resistance (ohm): 400 / 4k / 40k / 400k / 4M / 40M
- Altitude Used: 2000m, (storage) 12000m
- Capacitor Capacity (F): 50n / 500n / 5micro / 50micro / 100micro
- Dimensions (mm): 130x65x27
- Frequency (Hz): 50/500 / 5k / 50k / 100k
- Loading: 0.6 / 6/60/600
- Operating Humidity (%): Non-condensing (<10 degrees Celsius), <= 90% RH (10-30 degrees Celsius), <= 75% RH (30-40 degrees Celsius) (non-condensing)
- Operating/Storage Temperature (°C): 0 to + 40 / -30 to +60
- Power Supply: 2 AAA batteries
- Weight (g): 160
- FLUKE Clamp Meter (Tang Ampere)atribut:
- Dimensions (mm): 207 x 75 x 34
- Standard: CAT III 600 V, CAT IV 300 V
- DC Voltage (V): 600
- Continuity (ohm): 70 or less
- Weight (g): 265
- AC Current (A): 400
- AC Voltage (V): 600
- Resistance (ohm): 400/4000
- Wire Diameter (mm): ØUp to 300
- FLUKE Multimeter DigitalDeskripsi:This product gives users the means to quickly and easily do basic testing. It is easy to use and is packed with the features needed to repair most electrical problems.
- FLUKE ProcessmeterDeskripsi:Fluke 789 ProcessMeter doubles your troubleshooting power and is Fluke Connect-enabled. The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a loop calibrator with the power of a digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a display that's not only twice as large as the Fluke 787B, but also twice as bright with two levels of backlighting. And its built-in, selectable 250 ohm HART resistor eliminates the need to carry a separate resistor. The 789 also has a 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can add an optional temperature measurement module and the wireless data logging capabilities of the Fluke Connect mobile app to log data wirelessly to your smart phone and review it from a remote location. So now process technicians can do a lot more while carrying a lot less.atribut:
- Batteries: 4 AA alkaline batteries
- Electrical Safety: Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92
- Resistance Measurement (MΩ): 40, 0.2% + 1 LSD
- Diode Test: 2.0 V shoes diode voltage drop
- Auto Step, Auto Ramp: Yes
- Battery Life (hour): 140 typical (measurement), 10 typical (sourcing 20mA)
- Maximum Voltage (V) : 1000 RMS
- FLUKE Digital Clamp Meter with Flexible Clamp (Tang Ampere)Deskripsi:Tang Ampere Digital untuk mengukur arus listrik dan tegangan secara bersamaan dalam rentang ukur 1000A dan 1000V dan dapat di perbesar menjadi 2500A dalam arus AC (bolak balik) menggunakan tang fleksibel. Fluke 376 adalah pengganti dari tang ampere fluke 337atribut:
- Battery: 2 AA batteries, NEDA 15A, IEC LR6
- DC Current (A): 999.9
- Capacitor Capacity (F): 1000microF, Resolution: 0.1microF (<= 100microF), 1microF (<= 1000microF)
- Safety: CAN / CSA-C22.2 No.61010-1-04, ANSI / UL 61010-1: 2004, ANSI / ISA-61010-1 (82.02.01): 2004, EN / IEC 61010-1: 2001 ~, 1000V Measurement category (CAT) III, 600V Measurement category (CAT) IV, pollution degree 2, EN / IEC 61010-2-032: 2002, EN / IEC 61010
- Dimensions (mm): 246x83x43
- Weight (g): 388
- AC Voltage (V): 1000
- Altitude Used: 3000m
- DC Voltage (V): 1000
- Frequency Range (Hz): 5.0 to 500.0
- Measuring Range (mV): DC500
- Operating Humidity (%): Non-condensing (<10 degrees Celsius), ≤90% RH (10-30 degrees Celsius), ≤75% RH (30-40 degrees Celsius), ≤45% RH (40-50 degrees Celsius)
- Operating/Storage Temperature (°C): 10 to + 50 / -40 to + 60
- Resolution: 0.1A, 0.1V, 0.1mV, 0.1Hz
- FLUKE Termometer InframerahDeskripsi:Alat ukur temperatur permukaan benda kerja tanpa sentuh dengan inframerah memiliki rentang ukur -30 sampai dengan 600 derajat celcius yang memiliki waktu respon yang cepatatribut:
- Temperature Range (°C): -30 to 600 (-22 to 1112°F)
- FLUKE Tang Ampereatribut:
- Buzzer Sound: 30 ohm
- Battery: 2 AA batteries, NEDA 15A, IEC LR6
- AC Current (A): 600
- Weight (g): 370
- Altitude Used: 3000m, (storage) 12000m
- Capacitor Capacity (F): 10.0 ~ 100.0microF / 1000microF, Resolution: 0.1microF / 1microF
- Dimensions (H x W x D) (mm): 232x85x45
- Operating Humidity (%): Non-condensing (less than 10 degrees Celsius), 90 or less (10 to 30 degrees Celsius), 75 or less (30 to 40 degrees Celsius), 45 or less (40 to 50 degrees Celsius)
- Operating/Storage Temperature (°C): -10 to + 50 / -40 to +60
- Resistance (ohm): 600.0 / 6000, Resolution: 0.1 / 1
- Resolution: 0.1A
- Safety: ANSI / ISA S82.02.01: 2004, CAN / CSA-C22.2 No. 61010-1-04, IEC / EN 61010-1: 2001, 600V CAT III, 300V CAT IV, pollution degree 2, EN / IEC 1010- 2-32: 2002, EN / IEC 61010-031: 2002 / A1: 2008
- Voltage (V): 600 (DC); 600 (AC)
- FLUKE Pocket Thermal Cameraatribut:
- IFOV (spatial resolution): 7.6 mRad
- Infrared Resolution: 120x90 (10,800pixels)
- Field of View: 50°Hx38°V
- Distance to spot: 130:1
- Temperature Measurement Range (Not Calibrated Below -10°C): -20 °C to 400 °C
- Focus System: Fixed focus, minimum focus distance 22.8 cm
- USB: Mini USB used to transfer image to PC
- FLUKE Pressure GaugeDeskripsi:Product overview: Fluke 700G Pressure Gauge Calibrator. Designed for field pressure calibration, the Fluke 700G Series Pressure Gauge Calibrators give you the performance and durability that you have come to expect in Fluke pressure calibration products while being simple and easy-to-use. Whether you’re looking to connect to either a hydraulic or pneumatic test pump this series are designed to be a complete calibration solution with: - 23 pressure gauges. - Ranging ±10 inH2O/20 mbar to 10,000 psi/690 bar. With a standard accuracy of 0.05% of full scale and reference class gauges with accuracies of 0.04% you're sure to find a gauge that's the perfect fit for your application.
- FLUKE Cable Locator SetDeskripsi:The multipurpose solution to cable locationThe Fluke 2042 is a professional general purpose cable locator. It is ideal for tracing cables in walls and underground, locating fuses/breakers on final circuits and locating interruptions and short-circuits in cables and electrical floor heating systems. It can also be used for tracing metallic water and heating pipes. The unit is supplied as a complete kit comprising of a transmitter and receiver in a purpose-made carry case. The receiver also incorporates a torch function for working in dimly lit locations.atribut:
- Voltage Measurement Range (V): 12, 50, 120, 230, 400 (Transmitter)
- Frequency Range (Hz): 0-60 (Transmitter)
- Output Signal (kHz): 125 (Transmitter)
- Voltage (V): Up to 400 AC/DC (Transmitter)
- Tracing Depth Cable Location (m): 0-2.5 wall/underground cables (Receiver)
- Main Voltage Detection (m): 0-0.4 (Receiver)
- Batteries: Transmitter : 6x Batteries 1.5V; Receiver : 1x Battery 9V
- Dimensions (mm): Transmitter : 190x85x50; Receiver : 250x65x45
- Electrical Safety: EN 61010-1
- Humidity (without condensation) (%): Max. 80 relative (Transmitter and Receiver)
- Operating Altitude (m): Up to 2000 (Transmitter and Receiver)
- Operating Temperature (°C): 0 to 40 (Transmitter and Receiver)
- Overvoltage Category: Cat. III 300 V
- Storage Temperature (°C): -20 to +60 (Transmitter and Receiver)
- FLUKE Multimeter Digital True RMS (Multitester)atribut:
- Direct Current: 10A
- Alternating Current: 10A
- Resistance: 50MΩ
- Detection Method: True Effective Value Type (RMS)
- Maximum Display: 6000 counts
- Voltage (V): 1000 (DC); 1000 (AC)
- Width x Depth x Height: 90x43x185mm
- FLUKE Multimeter Digital (Multitester)Deskripsi:-Equipped with functions that are required to troubleshoot or repair the HVAC(heating, ventilating, air conditioning)system.-Detection Method:True Effective Value Type (RMS).-Power supply:Laminated type 9V dry batteryx1 (accessory).-A large white LED backlightatribut:
- DC Voltage: 600V
- AC Voltage (V): 600
- Resistance (MΩ): 40
- Alternating Current (A): 400
- Detection Method: True Effective Value Type (RMS)
- Direct Current: 10A
- Maximum Display: 6000 counts
- WxDxH (mm): 85x46x167
- FLUKE Infrared ThermometerDeskripsi:Fluke Infrared Thermometer memberikan akurasi penargetan laser tunggal. Memiliki laser tunggal dan rasio jarak ke titik 10: 1. Dapat digunakan untuk melakukan pengukuran suhu non-kontak pada transformator, motor, pompa, panel, pemutus, kompresor, saluran, saluran uap, katup, dan ventilasi. Ukurannya kecil dan sangat mudah digunakan. Laser tunggal membantu Anda menentukan target untuk pembacaan yang lebih akurat dan membuatnya lebih mudah untuk mengukur suhu di daerah yang sulit dijangkau. Dengan peringkat IP54 untuk ketahanan debu dan air, Anda dapat mengandalkan Fluke Infrared Thermometer untuk memberikan pengukuran suhu yang akurat dan berulang, hujan atau cerah, bahkan di lokasi industri yang paling kotor dan paling berdebu. Tahan dari kejatuhan setinggi 3 meter sehingga tidak perlu khawatir bahkan jika Anda bekerja dari tangga.atribut:
- Accuracy: ±1.5°C or ±1.5% of reading
- Emissivity: 0.10 to 1.00
- Temperature Range (°C): -30 to 500
- D:S Ratio: 10:1 (calculated at 90% energy)
- FLUKE Sound Level MeterDeskripsi:The Fluke 945 Sound Level Meter has been designed to meet the measurement requirements of safety Engineers, Health, Industrial safety offices and quality control in a wide variety of industrial environments. It offers two types of measurements: A weighting and C weighting. The A weighting is for general noise sound level and the C weighting is for measuring sound level of acoustic material control in various environments. The Fluke 945 conforms to the IEC651 Type 2, ANSI S1.4 Type 2, and JISC1502 requirements for Sound Level Meters. Applications: - Environmental Health and Safety testing and verification. - Sound testing for education environments. - Heavy and light industry sound testing. - Healthcare environment testing. - Safety testin.atribut:
- Display: 0.1 dB steps on 4-digit LCD screen
- Frequency Response: From 31.5 Hz to 8 kHz
- Safety Standard: CE, designed to meet IEC651 Type2, ANSI S1.4 Type 2
- Microphone: 0.5-inch electric condenser microphone
- Time Weighting: Fast slow
- FLUKE Infrared Cameraatribut:
- IFOV with Standard Lens: 0.93 mRad, D:S 1065:1
- Detector Resolution (pixels): 640x480
- Temperature Measurement Range (°C): ≤-20 to 1000 (-4 °F to 1832 °F) (not calibrated below -10 °C)
- Wireless Connectivity: Yes
- Accuracy: ±2 °C or 2% (at 25 °C nominal, whichever is greater)
- Advanced Manual Focus: Yes
- Built-in Digital Camera: 5 MP (visible light)
- Digital Zoom: 2x and 4x
- Infrared Resolution: 307, 200 pixels
- Laser Sharp Auto Focus: Yes, for consistently in-focus images
- Lens: Standard
- Multi Sharp Focus: Yes, focused near and far, throughout the field of view
- On-screen Emissivity Correction: Yes (both value and table)
- On-screen Transmission Correction: Yes
- Picture-In-Picture (PIP): Yes
- Ruggedized Touchscreen Display: 3.5 inch (landscape) 640x480 LCD
- Super Resolution: Captures and combines 4x the data to create a 1280 x 960 (614,400 pixels) image
- Thermal Sensitivity (NETD): ≤0.05 °C at 30 °C target temp (50 mK)
- FLUKE Particle CounterDeskripsi:Take a new look at indoor air quality.The Fluke 985 Particle Counter is the preferred choice for HVAC and IAQ professionals. From filter testing to IAQ investigations, the Fluke 985 is the portable solution for determining airborne particle concentrations. Use the Fluke 985 to immediately respond to occupant complaints, or as part of a comprehensive preventive maintenance program.With the Fluke 985 you can: Measure filter efficiencyMonitor industrial cleanroomsPre-screen indoor air quality and confidently work with IAQ specialistsLocate particle sources for remediationReport the effectiveness of repairs to customersDrive additional business by demonstrating the need for maintenance and repairWith a large screen, intuitive icons for navigation and on-screen data presentation, the Fluke 985 allows users to run more tests quickly, with less time spent cycling through screens to obtain the data. The Fluke 985 is lightweight and easy to use in any position and with easy data export options using USB cable, memory stick it's easy to review and analyze the data anywhere and anytime.atribut:
- Channels: 0.3μm, 0.5μm, 1.0μm, 2.0μm, 5.0μm, 10.0μm
- Flow Rate (cfm): 0.1
- Light Source (nm): 775 to 795, 90 mW class 3B laser
- Count Modes: Raw counts, #/m3, #/ft3, #/liter in Cumulative or Differential mode
- Counting Efficiency: 50% @ 0.3μm; 100% for particles > 0.45μm (per ISO 21501)
- Zero Count (count/minute): 1/5
- Alarms: Counts, low battery, sensor fail
- Calibration: PSL particles in air (NIST traceable)
- Communication mode: USB or Etheret
- Concentration Limits: 10% at 4,000,000 particles per ft3 (per ISO 21501)
- Data Storage: 10000 records (rotating buffer)
- Delay Time (hour): 0 to 24
- Dimensions (LxWxD) (cm): 27.2x9.9x5.3
- Humidity (%): Operation : < 95% non-condensing relative humidity; Storage : Up to 98% non-condensing relative humidity
- Operating Temperature (°C): 10 to 40
- Power Adapter: 100 V AC to 240 V AC, 12 V DC, 2.5 A
- Rechargeable Battery: Li-ion 7.4 V 2600 mAh; 10 hours typical use (5 hours continuous sampling) / 3.5 hours
- Sample Inlet: Isokinetic probe
- Security: Administrator password control (optional)
- Storage Temperature (°C): -10 to 50
- FLUKE Premium Test Pump KitDeskripsi:The Fluke 700HTP-2 is a hand operated hydraulic pressure pump designed to generate calibration pressures up to 10,000 psi/690 bar. Designed for use with Fluke-700 series high pressure modules such as the Fluke-700P09, 700P29, 700P30 and 700P31. Ideal for calibration when connected to a Fluke high pressure module via the reference port. The 700HTP-2 uses distilled water or mineral-based hydraulic oil as a source for calibration of high pressure input devices such as pressure transmitters or pressure gauges. Can also be used with Fluke 717 pressure calibrators.
- FLUKE True-RMS AC/DC Clamp MetersDeskripsi:Be ready for anythingThe Fluke True RMS Clamp Meter can read both AC and DC modes. Additionally, it is compatible with the new iFlex flexible current probe (sold separately), which increases the measurement range and provides increased display flexibility, and improved wire access.atribut:
- Operating Humidity (without condensation) (%): Non condensing (<10 °C); ≤90 RH (10 °C to 30 °C); ≤75 RH (30 °C to 40 °C); ≤45 RH (40 °C to 50 °C)
- Storage Altitude (m): 12000
- Storage Temperature (°C): -40 to 60
Daftar Harga fluke Terbaru November 2025
| FLUKE Infrared Thermometer | Rp1.399.900 |
| FLUKE Multimeter Digital (Multitester) | Rp1.199.900 |
| FLUKE Clamp Meter (Tang Ampere) | Rp6.399.900 |
| FLUKE Multimeter Digital | Rp2.899.900 |
| FLUKE Tang Ampere | Rp1.599.900 |
| FLUKE Processmeter | Rp34.999.900 |
| FLUKE Digital Clamp Meter with Flexible Clamp (Tang Ampere) | Rp20.999.900 |
| FLUKE Termometer Inframerah | Rp7.899.900 |
| FLUKE Tang Ampere | Rp9.999.900 |
| FLUKE Pocket Thermal Camera | Rp40.999.900 |
Data diperbarui pada 08/11/2025 (Harga belum termasuk PPN)