MG Lightning arrester for parallel connection type power supply

Sebelum PPN:
Rp1.999.900 - Rp2.999.900
Spesifikasi
Alarm OutputOutput (contact C) when the thermal disconnection circuit is activated or when the element is removed
Applicable wire size.Line: Depends on the crimp terminal selected. .Alarm output: 0.14 to 1.5 mm <sup>2</sup> , peel length 7 mm
Discharge Resistance (kA)20x2 times (8/20μs)
DisplayInspection window displays green (normal) or black (abnormal (thermal disconnection circuit activated))
Insulation Resistance (MΩ)Between line and alarm output: 100 or more/500V DC
KeyVoltage identification key: Identified by fitting the projection on the element with the keyhole on the base
Leakage Current (mA)1 or less
Limit Voltage (V)max1000「1.0 kA(8/20μs)」,max1500「5KA(8/20μs)」
Mass (g)About 100
Material (Housing)Flame retardant black resin
Maximum Operating Voltage (V)AC320
Minimum Applicable Load5V DC 1mA
MountingDIN rail mounting (For wall mounting, use the single unit mounting adapter (model: MBS))
Operating Humidity Range (%RH)30-90 (no condensation)
Operating Temperature Range (°C)-5~55
PerformanceSurge arrester required performance: JIS C5381-1 Class II, IEC 61643-1 Class II
Power Supply Voltage (V)220 AC
Protection ClassIP20 (when crimp terminals are covered with insulating caps)
Rated Load250 AC 0.5A (resistive load) 125 DC 0.2A (resistive load)
Response Time20ns or less
Safety FunctionBuilt-in thermal disconnection circuit
Starting Voltage (V)min460 (wave height value)
StructurePlug-in structure
Type of ConnectionLine: M5 screw terminal connection (self-lifting terminal) (tightening torque 2.5N.m) Alarm output: Connector type Euro terminal block (tightening torque 0.25N.m)
Withstand Voltage (V/minute)Between line and alarm output: 2000AC

Pilih jenis produk yang diinginkan

Nomor SKU Model Number Masa Persiapan Barang Harga Jumlah
Loading...
ask-button

Apakah produk dengan spesifikasi yang Anda inginkan belum tersedia? Hubungi tim Layanan Pelanggan kami di sini

Informasi Produk

Description
Protects electrical equipment from induced lightning surges that enter the power line.
A 1-port SPD that connects in parallel between the power line and neutral (ground).
Since it is a parallel connection type, it can be connected to electrical equipment without worrying about the load current.
Ultra-high withstand capacity type with discharge withstand capacity of 20 kA x 2 times (8/20 μs).
Since a zinc oxide type element (varistor) is used for the discharge element, there is no follow-on flow and it operates immediately in response to a lightning surge.
Even if the element part is removed, the power supply will not be cut off. Easy to inspect and replace.
Even if the element deteriorates and an overcurrent flows, it will be disconnected from the power supply line.
In addition, at the same time as displaying that the disconnection circuit has been activated, an alarm output notifies the outside of the abnormality.
The voltage identification key prevents erroneous insertion of the element part.
JIS C 5381-1 compliant application example: Installed on a low-voltage distribution board, combined with equipment with a large load current
Feature
Specification
Lightning protection method: Voltage-limiting 1-port SPD (according to IEC 61643-1) Discharge element: Zinc oxide element (varistor)